Microliter vials – Precisely manufactured for the smallest sample quantities

GC_HPLC_Vials_Übersicht

Microliter vials from LABC Precise removal of every drop – Made in Germany –Compatible with all common autosamplers “Vasen-Vial“ 1,2 ml Vµ-Vial The vial holds up to 1.2 ml, has a minimum residual volume of 15 µl and is Agilent-compatible. iV2µ-Vial – Insert – Vial The iV2µ vial holds 250 µl and is Agilent-compatible. With […]

Every microlitre counts

Vmax mit Boden

Originally, the text was written in 2021. It has lost little of its topicality. Often it is the little that counts and the VMAX bottom proves to be a clear advantage. Every microlitre is precious. The current pandemic has (also) taught us that. Medicines and vaccines, as the attentive pandemicist now knows, are a valuable […]

MOSH/MOAH analysis with ZeroSept®AIR

MOSH MOAH Kit

Contamination-free epoxidation within the scope of the MOSH/MOAH analytics with ZeroSept®AIR Food analysis is exposed to a latent risk of interference from interfering substances. These pose a problem because they affect the limits of quantification and accuracy in analysis. Sample preparation is therefore extremely time-consuming. Since interfering substances are also present in many solvents and/or […]

New opening of dein-laborshop.de

logo dein-laborshop.de

LABC-Labortechnik GmbH opens a new online shop for personal laboratory supplies: dein-laborshop.de. There you will find a large selection that you need for your laboratory use. In addition, we offer qualified customer service and fast shipping. Further information

Test on the tightness of the ZeroSept®AIR

Logo ZeroSept AIR

Vial closures with ZeroSept®AIR septum “PTFEvirginal/AIR/PTFEvirginal“ The new septum seal with an air cushion instead of an elastomer for standard vial closures. Due to its innovative design, the ZeroSept®AIR septum PTFEvirginal/AIR/PTFEvirginal has a high tightness, even with multiple injections! This makes the septum highly pure and, among other things, very interesting for trace analysis. It […]

ZeroSept®AIR Septum

ZeroSept_focus_kappe

An improved solution for vial closures in trace analysis ZeroSept®AIR-Septum offers improved vial closures for trace analysis. Unlike thin foil septa, it has comparable tightness, requires no tool adjustment, prevents the seals from falling out and elastomer components from penetrating the sample. It allows reproducible multiple injections and fits into common GC/HPLC systems with magnetic […]

Migration cells according to EN1186 with universal serial number

Migrationszellen komplett Edelstahl

Sieg-Mi-Flex stainless steel migration cells are now available with individual serial numbers and a factory certificate for individual proof of dimensional accuracy. Sieg-Mi-Flex cells have been used for migration simulations worldwide for many years. With this system, simulations can be performed in the temperature range from -15°C to 180°C as well as at high pressure […]

ND18 – VMAX with ND18 fine thread

VMAX mit Feingewinde

Übersicht Headspace vials come in a variety of sizes and materials to suit different applications. New on the market are the ND18 headspace vials with fine thread and VMAX bottom, which allow optimized liquid sample removal. The VMAX page summarises all the bottles, including a detailed description of the benefits. VMAX Assortment The entire VMAX […]

Which permeation device measures what?

draufsicht fluidpermcell

Field of application is the research of personal protective equipment (PPE) The transport of a substance through personal protective equipment (PPE) to human skin (permeation) should be prevented by wearing PPE. A maximum wearing time depends to a significant extent on the resistance of the personal protective equipment (PPE) to the respective hazardous substance and […]

VMAX – Sample vial with optimised residual volume emptying

gruppe vmax mit barcode web

VMAX – The sample vial with optimised residue emptying can be moulded to almost any vial, even retrofitted. The vials are suitable as sample or storage bottles and allow an almost complete withdrawal of the liquid by means of a cannula. Sample vials are usually emptied manually using a cannula. With standard vials, there is […]